VRF AIRSTAGE J-III (12,1 - 15,5 kW)

VRF AIRSTAGE J-III (12,1 - 15,5 kW)

VRF AIRSTAGE J-III (12,1 - 15,5 kW)

Ask about product

Product description

Air conditioning and heating systems for smaller buildings

 

  • Outdoor units models AJY040-54LBLAH (1pH), AJY040-54LELAH (3pH)
  • Indoor units total capacity for refrigerating system : 50-150 %
  • Number of indoor units in one cooling system:

    for AJY040... - 1-9 units

    for AJY045... - 1-10 units

    for AJY054... - 1-13 units

  • refrigerant R410A
  • High  EER COP, energy class "A"
  • Maximum pipe length: 120 m
  • Actual piping length : 180 m max.

  • Height difference between outdoor and indoor units : 50 m max.

  • Indoor units, controllers and monitoring software compatible with all AIRSTAGE VRF systems
  • Automatically adresses units in the system
  • High reliability of the system

  • Dedicated temp. range for cooling:   - 5~43°C
  • Dedicated temp. range for heating:   - 20~21°C
  • Design Simulator  for systems VRF J III

Product characteristic

  • Operation mode: cool, heat, dry, fan
  • Airflow intensity control by remote controller
  • Compract outdoor unit
  • Low sound level of outdoor unit
  • High reliability
  • Free configuration of indoor units type and capacity from 1,1 - 14,0 kW
  • Maximum of 9 or 13 indoor units connected to one refrigerant system
  • Indoor units connectable capacity is 150 % of the outdoor unit rating capacity
  • Flexible design and installation
  • Possible to control the indoor units by wireless or wired remote controller
  • Simple and quick installation owing to ready refrigerant systems components
  • Individual, group and central control available
  • Connectable to BMS systems (LonWorks, BACnet)
  • Control and service software

  • Remote monitoring available
  • Cooperation with SOLAR COOL system
Ask about product

Technical parameters

 cassette COMPACT

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

AUXB04

07/09/12/14/18/24

GALH

1,1 - 7,1

1,3 -8,0

300~1030

21-50

230/1/50

245x570x570

50x700x700

17,5-19,5

 

 CASSETTE

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

AUXD 18/24

AUXA 18/24/30/34/36/45/54

GALH

5,6 - 14,0

6,3 -16

870~2000

29-47

230/1/50

246x840x840

288x840X840

50x950X950

27,5-32,5

  

circular flow CASSETTE

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

AUXM 018/024/030 GLAH

AUXA 18/24/30/34/36/45/54

GALH

5,6 - 14,0

6,3 -16,0

810~2040

29-47

230/1/50

246x840x840

288x840X840

50x950X950

30,0-35,5

   

duct MINI

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXK

04/07/09/12/14/18/24

GCLH

1,1 - 7,1

1,3 - 8,0

370~1160

21-34

230/1/50

198x700x450

198x900x450

198x1100x450

15,5-22,5

0-30

0-50 

  

duct SLIM ceiling and floor

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXD

04/07/09/12/14/18/24

GALH

1,1 - 7,1

1,3 - 8,0

320~1330

20-35

230/1/50

198x700x620

198x900x620

198x1100x620

17-26

0-90

0-50 -ARXD24

 

duct MEDIUM STATIC PRESSURE 

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXA

24/30/36/45

GBLH

7,1 - 12,5

8,0 - 14,0

840~1970

23-43

230/1/50

270x1135x700

36-40

0-150

 

duct HIGH STATIC PRESSURE

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXC 

36/45

GBTH/GATH

11,2 - 12,5

12,5 - 14,0

1330~3500

32-49

230/1/50

400x1050x500

 

40-46

250

 

duct LARGE AIRFLOW

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXN

18/24/30/34/36/45

GATH

5,6-12,5

6,3-14,0

2280~4120

35-45

230/1/50

450x1587x700

84

50-100

50-300

 

FLOOR

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

AGYA 

004/007/009/012/014

GCAH (in. EEV)

1,1 - 4,0

1,3 - 4,5

280~670

28-46

230/1/50

600x740x200

15

AGYE

004/007/009/012/014

GCAH (out. EEV)

1,1 - 4,0

1,3 - 4,5

280~670

28-46

600x740x200

14,5

 

CEILING

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

ABYA 

30/36/45/54

GATH

9,0 - 14,0

10,0 - 16,0

1140~1780

33-45

230/1/50

240x1660x700

46-48

 

UNIVERSAL CEILING-FLOOR 

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

ABYA

12/14/18/24

3,6 - 7,1

4,0 - 8,0

490~1000

28-47

230/1/50

199x990x655

25-27

 

WALL MOUNTED

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

ASYA

004/007/009 GTAH

12/14 GACH

(in.EEV)

1,1 - 4,5

1,3 - 5,0

330~670

22-44

230/1/50

262x820x206

275x790x215

 

7,5

9,0

ASYE

004/007/009 GTAH

12/14 GACH

(out. EEV)

1,1 - 4,5

1,3 - 5,0

330~680

22-43

ASYA

18/24 GBCH

30/34 GTAH

5,6 - 10,0

6,3 - 11,2

690~1620

35-54

320x998x238

340x1150x280

15

18

 

duct OUTDOOR AIR

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXH

054/072/090

GTAH

14,0 - 28,0

8,9 - 17,4

1080~2100

42-47

230/1/50

425x1367x572

450x1583x700

48,0

55,0

71,0

50-185

50-200

50-240

 

DX-KIT

Indoor module

Capacity

C/H

Power

source

Dimensions

h x w x d

Weight

[kW] [V/f/Hz] [mm] [kg]

UTP-VX

30A/60A

+

UTY-VDGX

5,6-14,0

6,3-16,0

230/1/50

400x400x120

160x220x90

 

10+14

 

Outdoor units (1pH) 

Outdoor units

Nominal

capacity

EER

COP

Absorbed

power

Power

source

Dimensions

h x w x d

Weight

Dedicated

temp. range

[kW] [-] [kW] [V/Ph/Hz] [mm] [kg] [°C]

AJY040LBLAH

12,1

13,6

4,17

4,86

2,9

2,8

230/1/50

1334x970x370

117-119

- 5 ÷ 46

-20 ÷ 21

AJY045LBLAH

14,0

16,0

3,92

4,51

3,57

3,55

AJY054LBLAH

15,5

18,0

3,71

4,26

4,18

4,26

 

Outdoor units (3pH)

Outdoor units

Nominal

capacity

EER

COP

Absorbed

power

Power

source

Dimensions

h x w x d

Weight

Dedicated

temp. range

 

[kW]

[-]

[kW]

[V/Ph/Hz]

[mm]

[kg]

[°C]

AJY040LELAH

12,1

13,6

4,33

5,01

2,79

2,71

400/3/50

1334x970x370

118-119

- 5 ÷ 46

-20 ÷ 21

AJY045LELAH

14,0

16,0

4,05

4,7

3,46

3,40

AJY054LELAH

15,5

18,0

3,71

4,26

3,99

4,08

*Technical specifications concern selected models from Klima-Therm offer. Manufacturer continues to improve its products – to confirm the above data please contact the Authorised Dealer.

C-cooling, H-heating, airflow parameters are given for the highest fan speed,

Cooling/heating capacity is based on the following parameters:Cooling: indoor temperature: 27°CDB / 19°CWB, outdoor temperature: 35°CDB / 24°CWBHeating: indoor temperature: 20°CDB / 15°CWB, outdoor temperature: 7°CDB / 6°CWB.

CERTIFICATES, APPROVALS: CE, PZH

Ask about product

Usage

  • Residential and single-family dwellings,
  • Small office buildings,
  • Office and warehouse buildings,
  • School buildings,
  • Hotels, guest-houses,
  • Exhibition salons.

OPTIONS: 

  • Possible to control by wireless or wired remote controller
  • Individual, group and central remote controllers
  • Control software – electricity charge can be apportioned
  • Connectable to BMS systems
  • Remote monitoring
  • External switch controller – connectable card-keys
Ask about product