We use cookies to give you the best experience of our website and to provide anonymised, aggregated site usage data.
By closing this message, you consent to our use of cookies on this device in accordance with our cookie policy unless you have disabled them.
Close

VRF AIRSTAGE V-II ( 22,4 - 135,0 kW )

VRF AIRSTAGE V-II   ( 22,4 - 135,0 kW )

VRF AIRSTAGE V-II ( 22,4 - 135,0 kW )

Ask about product

Product description

Air conditioning and heating system - guarantee of the latest technology and high energy efficiency coefficients (EER/COP) 

 

  • Indoor units and sets - standard: AJYA72-90 LALH and AJY108-144 LALH
  • Outdoor units - high efficiency: AJY 144-396 LALHH
  • Cooling nominal capacity:   22,4 - 135 kW
  • Heating nominal capacity:   25,0 - 150 kW
  • High energy efficiency - "A" class
  • Refrigerant R410A
  • Indoor units total capacity for refrigerating system : 11,2 - 202,5 kW
  • Maximum of 48 indoor units
  • Long piping for high buildings
  • High system reliability
  • New central controller - PC software - up to 1600 indoor units
  • Touch control panel - central controller up to 400 indoor units
  • Dedicated temp. range for cooling: 15(-5)~46°C
  • Dedicated temp. range for heating; - 20~21°C
  • Design Simulator for VRF systems

Product characteristic

  • Operation mode: cool, heat, dry, fan
  • Airflow intensity control by remote controller
  • Maximum 3 outdoor units connectable to one refrigerant system
  • Low sound level of outdoor unit
  • High reliability owing to the set of compressors (compressor substitution mode)
  • Unique combination of inverter compressor with constant speed compressors
  • Compressors rotary operation with constant efficiency
  • High efficiency subcool heat exchanger
  • Oil level balance control
  • Free configuration of indoor units type and capacity from 2,15 - 25 kW
  • Maximum of 48 indoor units connected to one refrigerant system
  • Indoor units connectable capacity is 150 % of the outdoor unit rating capacity
  • Precise room temperature control owing to Inverter technology
  • Super quiet wall type indoor units
  • Maximum piping length 1000 m
  • Maximum height difference 50 m
  • Proper operation in heating mode in low ambient outdoor temperature
  • Flexible design and installation
  • Outdoor unit fan with standard static pressure of 80 Pa
  • Reduction of the refrigerant piping installation space owing to possibility of outdoor units connection
  • Possible to control the indoor units by wireless or wired remote controller
  • Simple and quick installation owing to ready refrigerant systems components
  • Individual, group and central control available
  • Connectable to BMS systems (LonWorks, BACnet)
  • Control and service software
  • Remote monitoring available
Ask about product

Technical parameters

cassette COMPACT

Indoor units

Capacity

C/H

Air flow rate

Sound pressure

level

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

AUXB04

07/09/12/14/18/24

GALH

1,1 - 7,1

1,3 -8,0

300~1030

21-50

230/1/50

245x570x570

50x700x700

17,5-19,5

 

 CASSETTE

Indoor unit

Capacity

C/H

Air flow

rate

Sound pressure

level

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

AUXD 18/24

AUXA 18/24/30/34/36/45/54

GALH

5,6 - 14,0

6,3 -16

870~2000

29-47

230/1/50

246x840x840

288x840X840

50x950X950

27,5-32,5

 

 

  

circular flow CASSETTE

Indoor units

Capacity

C/H

Air flow

rate

Sound pressure

level

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

AUXM 018/024/030 GLAH

AUXK 18/24/30/34/36/45/54

GALH

5,6 - 14,0

6,3 -16,0

810~2040

29-47

230/1/50

246x840x840

288x840X840

50x950X950

30,0-35,5

 

   duct MINI  

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXK

04/07/09/12/14/18/24

GCLH

1,1 - 7,1

1,3 - 8,0

370~1160

21-34

230/1/50

198x700x450

198x900x450

198x1100x450

15,5-22,5

0-30

0-50 

 

  duct SLIM ceiling and floor

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXD

04/07/09/12/14/18/24

GALH

1,1 - 7,1

1,3 - 8,0

320~1330

20-35

230/1/50

198x700x620

198x900x620

198x1100x620

17-26

0-90

0-50 -ARXD24

 

 

duct MEDIUM STATIC PRESSURE 

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXA

24/30/36/45

GBLH

7,1 - 12,5

8,0 - 14,0

840~1970

23-43

230/1/50

270x1135x700

36-40

0-150

 

 duct HIGH STATIC PRESSURE

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXC 

36/45/60/72/90

GBTH/GATH

11,2 - 28,0

12,5 - 31,5

1330~4850

32-49

230/1/50

400x1050x500

450x1587x700

550x1587x700

40-105

250

300

 

  duct LARGE AIRFLOW

indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXN

18/24/30/34/36/45

GATH

5,6-12,5

6,3-14,0

2280~4120

35-45

230/1/50

450x1587x700

84

50-100

50-300

 

 FLOOR

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

AGYA 

004/007/009/012/014

GCAH (out. EEV)

1,1 - 4,0

1,3 - 4,5

280~670

28-46

230/1/50

600x740x200

15

AGYE

004/007/009/012/014

GCAH (out. EEV)

1,1 - 4,0

1,3 - 4,5

280~670

28-46

600x740x200

14,5

 

 CEILING

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

ABYA 

30/36/45/54

GATH

9,0 - 14,0

10,0 - 16,0

1140~1780

33-45

230/1/50

240x1660x700

46-48

 

 UNIVERSAL CEILING-FLOOR

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

ABYA

12/14/18/24

3,6 - 7,1

4,0 - 8,0

490~1000

28-47

230/1/50

199x990x655

25-27

 

WALL MOUNTED

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg]

ASYA

004/007/009 GTAH

12/14 GACH

(in.EEV)

1,1 - 4,5

1,3 - 5,0

330~670

22-44

230/1/50

262x820x206

275x790x215

 

7,5

9,0

ASYE

004/007/009 GTAH

12/14 GACH

(in. EEV)

1,1 - 4,5

1,3 - 5,0

330~680

22-43

ASYA

18/24 GBCH

30/34 GTAH

5,6 - 10,0

6,3 - 11,2

690~1620

35-54

320x998x238

340x1150x280

15

18

 

 duct OUTDOOR AIR

Indoor units

Capacity

C/H

Air flow

rate

Sound

pressure

Power

source

Dimensions

h x w x d

Weight

Static

pressure

[kW] [m³/h] [dB(A)] [V/f/Hz] [mm] [kg] [Pa]

ARXH

054/072/090

GTAH

14,0 - 28,0

8,9 - 17,4

1080~2100

42-47

230/1/50

425x1367x572

450x1583x700

48,0

55,0

71,0

50-185

50-200

50-240

 

 DX-KIT

Indoor module

Capacity

C/H

Power

source

Dimensions

h x w x d

Weight

[kW] [V/f/Hz] [mm] [kg]

UTP-VX

30A/60A/90A/90Ax2

+

UTY-VDGX

5,6-50,4

6,3-56,2

230/1/50

400x400x120

160x220x90

160x220x90 x 2 

10+14

 

 

Outdoor units, SAVING SPACE COMBINATION

Outdoor units

Capacity

C/H

EER

COP

Dedicated

temp. range

[kW] [-] [°C]

AJYA 72/90/108 LALH

22,4/28,0/33,5

25,0/31,5/37,5

4,07/3,62/3,48

4,37/4,02/4,04

-15 ÷ 46

 

-20 ÷ 21

AJY 126/144 LALH

40,0/45,0

45,0/50,0

3,47/3,18

3,93/3,97

AJY 162/180/198/216 LALH

50,4/55,9/61,5/67,0

56,5/62,5/69,0/75,0

3,81/3,69/3,54/3,48

4,17/4,17/4,03/4,04

- 5 ÷ 46 

-20 ÷ 21

AJY 234/252/270/288 LALH

73,5/78,5/85,0/90,0

82,5/87,5/95,0/100,0

3,52/3,36/3,41/3,31

4,05/3,91/4,01/3,92

AJY 306/324/342/360 LALH

95,0/100,5/107,0/112,0

106,5/112,5/120,0/125,0

3,57/3,44/3,50/3,38

4,01/3,90/4,00/3,91

AJY 378/396/414/432 LALH

118,5/123,5/130,0/135,0

132,5/137,5/145,0/150,0

3,44/3,34/3,37/3,31

4,00/3,91/3,98/3,92

Outdoor units, HIGH EFFICIENCY COMBINATION

Outdoor units

Capacity

C/H

EER

COP

Dedicated

temp. range

[kW] [-] [°C]

AJY 144/198 LALHH

44,8/62,4

50,0/70,0

4,11/3,72

4,39/4,22

- 5 ÷ 46 

-20 ÷ 21

AJY 216/234 LALHH

67,2/72,8

75,0/81,5

4,11/4,04

4,39/4,35

AJY 252/270 LALHH

78,3/84,8

87,5/95,0

3,99/3.94

4,32/4,30

AJY288/306 LALHH

89,4/95,9

100,0/107,5

3,78/3,76

4,24/4,23

AJY 324/360 LALHH

102,4/113,5

115,0/127,5

3,58/3,47

4,02/3,96

AJY 378/396 LALHH

120,0/125,0

135,0/140,0

3,53/3,44

4,13/4,05

*Technical specifications concern selected models from Klima-Therm offer. Manufacturer continues to improve its products – to confirm the above data please contact the Authorised Dealer.

C-cooling, H-heating, airflow parameters are given for the highest fan speed,

Cooling/heating capacity is based on the following parameters:Cooling: indoor temperature: 27°CDB / 19°CWB, outdoor temperature: 35°CDB / 24°CWBHeating: indoor temperature: 20°CDB / 15°CWB, outdoor temperature: 7°CDB / 6°CWB.

CERTIFICATES, APPROVALS: CE, PZH

Ask about product

Usage

  • Residential and single-family dwellings,
  • High office buildings,
  • Office and warehouse buildings,
  • School buildings,
  • Hotels, guest-houses,
  • Exhibition salons.

OPTIONS: 

  • Possible to control by wireless or wired remote controlle
  • Individual, group and central remote controllers
  • Possibility of connecting the Split type units to the control system
  • Control software – electricity charge can be apportioned
  • Connectable to BMS systems
  • Remote monitoring
  • External switch controller – connectable card-keys
Ask about product