Multi Split : (4,0 - 10,1 kW) [2-3-4 rooms]

Multi Split : (4,0 - 10,1 kW) [2-3-4 rooms]

Multi Split : (4,0 - 10,1 kW) [2-3-4 rooms]

Ask about product

Product description

Multi Split

 

  • Outdoor units - cooling nominal capacity: 4,0~8,0 kW
  • Outdoor units - heating nominal capacity: 4,4~9,6 kW
  • Indoor units - cooling nominal capacity: 2,0~7,0 kW
  • Construction of the system: 2, 3 or 4 indoor units + one outdoor unit
  • Individual piping to each air-conditioners
  • Energy-saving
  • DC Inverter technology
  • Refrigerant : R 410A
  • Max. length pipe : 30 - 70 m
  • Max. height difference pipe : 15 m
  • Dedicated temperature range - cooling :  - 10 ÷ 10~46°C

  • Dedicated temperature range - heating : - 15 ÷ -10~24°C

Product characteristic

  • Operation mode: cool, heat, dry, fan
  • Airflow intensity control by remote controller
  • 20 indoor units selection range
  • Indoor units: wall, cassette, duct, ceiling-universal type
  • Possible to connect higher capacity indoor units with relation to outdoor unit capacity
  • Total piping length up to 70m
  • Multi system for 2, 3 or 4 rooms (depending on the outdoor unit)
Ask about product
All DC Inverter

Technical parameters

Multi Split

 

Indoor units - wall mounted ASYG

 

Indoor

units

Capacity

cooling

Airflow

Sound

pressure level

Power

supply

Dimensions

h x w x d

Net

weight

Ref.

instalation

- [kW] [m³/h] [dB(A)] [V/Ph/Hz] [mm] [kg] [mm]

ASYG07LUCA

2,0

330~570

21/28/30/35

230/1/50

282x870x185

9,5

ø 6,35

ASYG09LUCA

2,5

330~600 21/28/32/36 230/1/50 282x870x185 9,5

ø 6,35

ASYG12LUCA

3.5

330~660

21/31/34/37

230/1/50

282x870x185

9,5

ø 6,35

ASYG14LUCA

4,0

390~710

25/33/36/41

230/1/50

282x870x185

9,5

ø 6,35

ø 12,70

ASYG07LMCA

2,0

310~560

21/29/32/36

230/1/50

280x790x203

8,0

ø 6,35

ø 9,52

ASYG09LMCA

2,5

310~600

21/29/33/37

230/1/50

280x790x203

8,0

ø 6,35

ø 9,52

ASYG12LMCA

3,5

310~660

21/30/36/40

230/1/50

280x790x203

8,0

ø 6,35

ø 9,52

ASYG14LMCA

4,3 

-

-

230/1/50

-

-

-

ASYG18LFCA

5,0

550~900

26/33/37/43

230/1/50

320x998x238

14,0

ø 6,35

ø 12,70

ASYG24LFCC

7,0

620~1120

33/37/42/49

230/1/50

320x998x238

14,0

ø 6,35

ø 15,88

Indoor units - floor, floor/ceiling AGYG, ABYG

 

Indoor

units

Capacity

cooling

Airflow

Sound

pressure level

Power

supply

Dimensions

h x w x d

Net

weight

Ref.

instalation

- [kW] [m³/h] [dB(A)] [V/Ph/Hz] [mm] [kg] [mm]

AGYG09LVCA

2,5

270~530

22/28/34/39

230/1/50

600x740x200

14,0

ø 6,35

ø 9,52

AGYG12LVCA

3,5

270~600 22/30/36/42 230/1/50

600x740x200

14,0 ø 6,35

ø 9,52

AGYG14LVCA

4,0

270~650

22/31/38/44

230/1/50

600x740x200

14,0

ø 6,35

ø 12,70

ABYG14LVTA

4,0

480~640

29/33/34/36

230/1/50

199x990x655

27,0

ø 6,35

ø 12,70

ABYG18LVTB

5,0

500~780

32/34/38/41

230/1/50

199x990x650

27,0

ø 6,35

ø 12,70

Indoor units - compact cassette AUYG

 

Indoor

units

Capacity

cooling

Airflow

Sound

pressure level

Power

supply

Dimensions

h x w x d

Net

weight

Ref.

instalation

- [kW] [m³/h] [dB(A)] [V/Ph/Hz] [mm] [kg] [mm]

AUYG07LVLA

2,0

390~540

27/29/31/33

230/1/50

245x570x570

15,0

ø 6,35

ø 9,52

AUYG09LVLA

2,5

390~540

27/29/31/33

230/1/50

245x570x570

15,0

ø 6,35

ø 9,52

AUYG12LVLB

3,5

410~610 28/31/33/37 230/1/50

245x570x570

15,0 ø 6,35

ø 9,52

AUYG14LVLB

4,0

410~680

29/32/35/40

230/1/50

245x570x570

15,0

ø 6,35

ø 12,70

AUYG18LVLB

5,0

410~750

29/33/37/42

230/1/50

245x570x570

15,0

ø 6,35

ø 12,70

Indoor units - Slim duct ARYG

 

Indoor

units

Capacity

cooling

Airflow

Sound

pressure level

Power

supply

Dimensions

h x w x d

Net

weight

Static

pressure

- [kW] [m³/h] [dB(A)] [V/Ph/Hz] [mm] [kg] [Pa]

ARYG07LLTA

2,0

440~550

24/25/26/28

230/1/50

198x700x620

17,0

0 - 90

ARYG09LLTA

2,5

450~600 25/26/27/28 230/1/50

198x700x620

19,0 0 - 90

ARYG12LLTB

3.5

480~650

26/27/28/29

230/1/50

198x700x620

19,0

0 - 90

ARYG14LLTB

4,0

480~800

26/28/30/32

230/1/50

198x700x620

19,0

0 - 90

ARYG18LLTB

5,0

750~940

29/30/31/32

230/1/50

198x700x620

23,0

0 - 90

Outdoor units AOYG

 

Outdoor units

 

Capacity

C / H

Airflow

Input

power

Power

supply

Dimensions

h x w x d

Net

weight

Dedicated

temperature

range

-[kW][m3/h][kW][V/Ph/Hz][mm][kg][°C]

AOYG14LAC2

4,00 (1,4~4,4)

4,40 (1,1~5,4)

1850

1,090

1,030

230/1/50

540x790x290 

37 

 10÷46

-15÷24

 AOYG18LAC2

5,00 (1,7~5,6)

5,60 (1,8~6,1)

2050

1,560

1,410

230/1/50

540x790x290

38

 10÷46

-15÷24

AOYG18LAT3

5,40 (1,8~6,8)

6,80 (2,0~8,0)

3050

1,350

1,620

230/1/50

700x900x330

55

-10÷46

-15÷24

AOYG24LAT3

6,80 (1,8~8,5)

8,00 (2,0~9,2)

3300

1,940

2,000

230/1/50 

700x900x330

 55

-10÷46

-15÷24

AOYG30LAT4

8,00 (3,5~10,1)

9,60 (3,7~12,0)

3500

2,220

2,400

230/1/50 

 830x900x330

68

 0÷46

-10÷24

*Technical specifications concern selected models from Klima-Therm offer. Manufacturer continues to improve its products – to confirm the above data please contact the Authorised Dealer.

C-cooling, H-heating, airflow parameters are given for the highest fan speed, Cooling/heating capacity is based on the following parameters:Cooling: indoor temperature: 27°CDB / 19°CWB, outdoor temperature: 35°CDB / 24°CWBHeating: indoor temperature: 20°CDB / 15°CWB, outdoor temperature: 7°CDB / 6°CWB

CERTIFICATES, APPROVALS: CE, PZH

Ask about product

Usage

  • Residential rooms, single-family dwellings,
  • Office rooms,
  • Hotels, guest-houses.
Ask about product