Water cooled chillers, Turbocor compressors, flooded shell and tube heat exchanger with energy rating A, environmentally friendly refrigerant R134A designed for Dry Cooler.

 

Innovative chillers have been designed to comply with particularly high specification demands on air conditioning equipment and systems.

  • Turbocor compressors
  • 2-year warranty
  • Energy efficiency class A
  • Environmentally friendly refrigerant R134A
  • Designed for Dry Cooler

 

Chilled water systems – Turbocor compressors – Class A – R134a refrigerant – Dry Cooler
See the most important functions
R134a refrigerant
R134a refrigerant
Class A
Class A
Turbocor compressors
Turbocor compressors
Cooling only version
Cooling only version
Flooded Shell & Tube exchanger
Flooded Shell & Tube exchanger
R134a refrigerant
R134a refrigerant
R134a refrigerant

Units with the refrigeration system containing R134a (GWP 1430) refrigerant.

Class A
Class A
Class A

Units with high energy efficiency confirmed by the EER and ESEER ratios in class A.

Turbocor compressors
Turbocor compressors
Turbocor compressors

Semi-hermetic, two-stage, centrifugal Turbocor compressors, without lubrication system, with magnetically levitating rotor, thermal protection, discharge and suction check valves, stepless capacity control system provided by the built-in inverter, and automatic anti-cavitation system. The power supply system of the compressor is equipped with a set of electrolytic capacitors to maintain levitation in the event of a power failure, a power factor correction choke, and an EMI filter (electromagnetic compatibility).

Cooling only version
Cooling only version
Cooling only version

The units in the cooling-only version provide the basic function of cooling water, chilled water or air, while other functions are optional.

Flooded Shell & Tube exchanger
Flooded Shell & Tube exchanger
Flooded Shell & Tube exchanger

High efficiency flooded shell and tube heat exchanger with one or two independent cooling circuits and one water circuit.

Technical specifications

Agregat

 

EER

 

Wydajność

Pobór mocy

Zasilanie

Wymiary

Masa

Ładunek czynnika

 

 

kW

kW

V/pH/Hz

mm

kg

kg (CO2eq-T)

CWW/TTY/DR 1601-1

4,26

298

70

400/3/50

1800/3400/1100

1840

145(207,350)

CWW/TTY/DR 2001-1

4,29

395

92

400/3/50

1850/3400/1150

2115

150(214,500)

CWW/TTY/DR 3002-1

4,24

598

141

400/3/50

1950/3400/1150

2955

205(293,150)

CWW/TTY/DR 4002-1

4,26

792

186

400/3/50

2000/3400/1250

3430

245(350,350)

CWW/TTY/DR 4203-1

4,24

894

211

400/3/50

2000/3400/1700

3855

250(357,500)

CWW/TTY/DR 5103-1

4,28

1185

277

400/3/50

2050/3450/1800

4415

295(421,850)

CWW/TTY/DR 6204-1

4,26

1584

372

400/3/50

2100/4500/1750

7555

610(872,300)

 

Dane techniczne dotyczą wybranych modeli z oferty Klima-Therm. Producent stale udoskonala swoje wyroby – aby zweryfikować dane proszę skontaktować się z Autoryzowanym Dealerem. Nominalna wydajność chłodzenia wyznaczana jest dla następujących parametrów: medium chłodzone: glikol etylenowy 35%, temperatura medium chłodzonego 12°/7°C, temperatura wody chłodzącej skraplacz 40°/45°C;

Expand the entire table
Hide
Download

Do you need more documentation?

Check the Klima-Therm technical portal.
See the technical documentation portal

Explore projects

Find out where we installed chilled water systems
Browse references
Other products in this category