Air cooled multifunctional heat pumps Energy Power series intended for use with 4-pipe systems.

 

Energy Power units are innovative air cooled multifunctional devices dedicated to use in 4-pipe systems. Equipped with two sections, one for the production of chilled water and the other for the production of hot water. Simultaneous production of cold and hot water.

  • Scroll compressors
  • 2-year warranty
  • Designed for 4-pipe systems
  • Energy Power technology
  • Refrigerants: R410A, R452B, R454B

 

Chilled water systems – Scroll compressor – 4-pipes systems
See the most important functions
DHW
DHW
R410A refrigerant
R410A refrigerant
Scroll compressors
Scroll compressors
Axial fans
Axial fans
Cooling - heating version
Cooling - heating version
Cooling only version
Cooling only version
Heating only version
Heating only version
Plate heat exchanger
Plate heat exchanger
R454B refrigerant
R454B refrigerant
R452B Refrigerant
R452B Refrigerant
DHW
DHW
DHW

Units which prepare domestic hot water.

R410A refrigerant
R410A refrigerant
R410A refrigerant

Units with the refrigeration system containing R410A (GWP 2088) refrigerant.

Scroll compressors
Scroll compressors
Scroll compressors

Scroll compressor with an oil sight glass. Installed with internal overheating protection and, if required, with a crankcase heater, fitted on rubber vibration dampers.

Axial fans
Axial fans
Axial fans

Axial fans directly coupled to a three phase electric motor and external rotor, equipped with a grille protecting the fan located at the air outlet.

Cooling - heating version
Cooling - heating version
Cooling - heating version

Units in the cooling/heating version operate using the heat pump function. They can cool or heat water, chilled water or air.

Cooling only version
Cooling only version
Cooling only version

The units in the cooling-only version provide the basic function of cooling water, chilled water or air, while other functions are optional.

Heating only version
Heating only version
Heating only version

The units in the heating-only version only serve to heat water or air. Their primary function is heating, while other functions are optional.

Plate heat exchanger
Plate heat exchanger
Plate heat exchanger

Plate heat exchanger made of AISI 316 stainless steel, soldered, with one cooling circuit and one water circuit or with two independent cooling circuits and one water circuit.

R454B refrigerant
R454B refrigerant
R454B refrigerant

Units with the refrigeration system containing R454B (GWP 466) refrigerant.

R452B Refrigerant
R452B Refrigerant
R452B Refrigerant

Units with the refrigeration system containing R452B (GWP 675) refrigerant.

Technical specifications

Model

 

 

EER

COP

 

Capacity

C/H

 

Absorbed power

C/H

 

TER

 

 

Capacity

C+H

C/H

Absorbed power

C+H

 

Electric power supply

 

 

Dimensions

 

 

Weight

 

 

Refrigerant charge

 

 

    kW kW   kW kW V/pH/Hz mm kg kg (CO2eq-T)
CHA/K/EP 604-P 2,93 167 57 7,80 170 50 400/3/50 2100/3350/2200 2253 2x25(2x52,200)
3,25 180 55 220
CHA/K/EP 724-P 2,75 190 69 7,50 195 60 400/3/50 2100/3350/2200 2279 2x26(2x54,288)
3,2 204 64 255
CHA/K/EP 804-P 2,91 218 75 7,39 214 67 400/3/50 2100/3350/2200 2397 2x30(2x62,640)
3,22 231 72 281
CHA/K/EP 904-P 2,84 241 85 7,48 243 75 400/3/50 2100/3350/2200 2439 2x32(2x66,816)
3,25 257 79 318
CHA/K/EP 1004-P 2,84 264 93 7,67 270 81 400/3/50 2100/3350/2200 2469 2x33(2x68,904)
3,28 281 86 351
CHA/K/EP 1104-P 2,89 301 104 7,52 303 93 400/3/50 2100/5000/2200 3232 2x38(2x79,344)
3,28 318 97 396
CHA/K/EP 1204-P 2,86 332 116 7,38 335 105 400/3/50 2100/5000/2200 3467 2x44(2x91,872)
3,35 379 113 440
CHA/K/EP 1404-P 2,98 385 129 7,59 386 117 400/3/50 2100/6200/2200 4394 2x55(2x114,840)
3,4 439 129 503
CHA/K/EP 1604-P 2,99 428 143 7,51 427 131 400/3/50 2100/6200/2200 4574 2x55(2x114,840)
3,34 478 143 558
CHA/K/EP 1804-P 2,84 472 166 7,77 491 145 400/3/50 2100/6200/2200 4572 2x70(2x146,160)
3,42 541 158 636
CHA/K/EP 2004-P 2,7 507 188 7,72 541 161 400/3/50 2100/7200/2200 5214 2x70(2x146,160)
3,35 587 175 702

Technical data refer to selected models from the Klima-Therm offer. The manufacturer is constantly improving its products – to verify the data, please contact an Authorized Dealer. C - cooling, H – heating. Cooling capacity- Chilled water from 12 to 7 °C, ambient temperature  35°C; Heating capacity- heating water 40°/45°C, ambient temperature 7°C.

The models 604-P÷1404-P are compliant to ErP Regulations. The models 1604-P÷2004-P are compliant to ErP 2021 Regulations for comfort cooling application if provided with EC or ECH accessory (EC Inverter fans).

Expand the entire table
Hide
Download

Do you need more documentation?

Check the Klima-Therm technical portal.
See the technical documentation portal

Explore projects

Find out where we installed chilled water systems
Browse references
Other products in this category